We recently received a question about Unistrut Post Base tension loads from one of our clients and decided to share the response with our loyal Tech Talk readers.
Two of the most popular post bases in the Unistrut catalog are P2072A and P2072A-SQ. If you want to learn more about the differences between these fittings, we suggest checking out our recent Tech Talk article on Unistrut Post Bases. Now let’s take a look at the load data, starting with the P2072A:
Unistrut P2072A Design Load Report | ||
---|---|---|
Average Ultimate Tension (lbs.) | Design Tension Load (lbs.) | Average Deflection at Design Tension Load |
11.200 | 3,000 | 0.056" |
1. Average Ultimate Load from Test T-067 2. Testing based on 1/2"-13 channel nut & cap screw torqued to 50 ft-lbs. 3. Average safety factor = 3.7 4. Design load limited to 3,000 lb. slip load of two (2) 1/2"-13 channel nuts, SF=3 5. Deflection is the average deflection reading at 3,000 lbs. 6. Deflection is measured in the direction of the tension load. |
Here’s the load data for the Unistrut P2072A-SQ post base:
Unistrut P2072A-SQ Design Load Report | ||
---|---|---|
Average Ultimate Tension (lbs.) | Design Tension Load (lbs.) | Average Deflection at Design Tension Load |
11.400 | 3,000 | 0.067" |
1. Average Ultimate Load from Test T-065 2. Testing based on 1/2"-13 channel nut & cap screw torqued to 50 ft-lbs. 3. Average safety factor = 3.9 4. Design load limited to 3,000 lb. slip load of two (2) 1/2"-13 channel nuts, SF=3 5. Deflection is the average deflection reading at 3,000 lbs. 6. Deflection is measured in the direction of the tension load. |
**Downloadable PDF’s**
P2072A Tension Load Report
P2072A-SQ Tension Load Report
As always, if you have technical questions about Unistrut fittings and channel, need pricing, or wish to place an order, contact Unistrut Service Company for further assistance.